Application: Electronic, Instrument, Position Sensor, Audio, Lighting, Power
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Measurement
Winding Form: Single Layer & Tightly Wound Type
Samples:
US$ 2/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Anhui, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (34)

Basic Info.

Insulating Medium
Insulating Paper
Installation
Penetration Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
According to Customer Demand
Specification
According to customer demand
Trademark
Ecriee-Tamura
Origin
China
HS Code
850431
Production Capacity
50000piece/Month

Product Description


Descripition of Plastic Shell Type Current Transformer

*Low-voltage plastic shell type current transformers are a series of plastic enclosures that are fully enclosed. They are suitable for electrical energy measurement, electrical energy measurement, and relay protection in power systems with a rated frequency of 50 Hz/60 Hz and a rated voltage of 0.66 kV and below.    
 
*The primary current of standard product could be 5000A, and the highest accuracy could be 0.2 class. Special products such as higher current or higher accuracy can be customized.   
     
* The products meet the current transformer standards of IEC61869-2:2012 and GB20840.2-2014.  
     
*The products are environment-friendly and lead-free, comply with RoHS directive.


Specification
 
Item No. Rated current ratio (A) Accuracy class and rated load(VA) Dimension(mm) Number of turns through core  Bars
(mm) / Qty
Max. outer diameter of cable(mm)
0.2class  0.5class 1.0class W H D
30I 100/5(1)   2.5   60 80 37 1 30*10/1 φ22
200/5(1)   3.75   1
300/5(1)   5   1
400/5(1)   5   1
500/5(1)   10   1
600/5(1)   10   1
40I 200/5(1)   2.5   75 98 40 1 40*10/1 φ30
300/5(1)   5   1
400/5(1)   5   1
500/5(1)   10   1
800/5(1)   10   1
1000/5(1) 10     1
50I 200/5(1)   2.5   82 98 40 1 50*10/1
50*6/1~2
φ34
300/5(1)   5   1
500/5(1)   10   1
800/5(1)   10   1
1000/5(1) 10     1
1200/5(1) 10     1
1500/5(1) 20     1
60I 200/5(1)   2.5   102 125 40 1 60*10/1
60*8/1~2
60*6/1~3
φ44
300/5(1)   5   1
500/5(1)   10   1
800/5(1)   10   1
1000/5(1) 10     1
1200/5(1) 10     1
1500/5(1) 20     1
2000/5(1) 20     1
2500/5(1) 30     1
80I 200/5(1)   2.5   125 118 40 1 80*10/1
80*8/1~2
80*6/1~3
φ50
300/5(1)   5   1
400/5(1)   5   1
500/5(1)   10   1
800/5(1)   10   1
1000/5(1) 10     1
1200/5(1) 10     1
1500/5(1) 20     1
2000/5(1) 20     1
2500/5(1) 30     1
3000/5(1) 30     1
100I 300/5(1)   5   168 136 40 1 100*10/1~2
100*8/1~3
100*6/1~4
φ56
500/5(1)   10   1
800/5(1)   10   1
1000/5(1) 10     1
1200/5(1) 10     1
1500/5(1) 20     1
2000/5(1) 20     1
2500/5(1) 30     1
3000/5(1) 30     1
120I 500/5(1)   10   186 135 45 1 120*10/1~3
120*8/1~4
φ60
800/5(1)   10   1
1000/5(1) 10     1
1200/5(1) 10     1
1500/5(1) 20     1
2000/5(1) 20     1
2500/5(1) 30     1
3000/5(1) 30     1
3500/5(1) 30     1
5000/5(1) 30     1


Notes
*The current transformer is allowed to be connected to an AC circuit not exceeding 0.66kv, and the long-term working current not exceed 1.1 times the rated value, and 1.2 times the rated current is allowed to be used for a short time, and the working time does not exceed 1 hour, except for non-standard and protection.

*When the measuring instrument is connected to S1 and S2 terminals, it must to be noted that the total impedance (including wiring) of the connected instrument does not exceed the rated load of the current transformer.

*It is strictly forbidden to open the secondary circuit of the current transformer during operation. If the secondary coil is open circuit when it is powered o accidentally , demagnetization must be carried out to reduce the increase of error.

*The current transformer is only used in places without direct invasion of rain and snow,no serious pollution ,no severe vibration ,no corrosive metal and dust or steam damaging insulation.


Advantage

*High quality oriented and low loss steel to ensure the accuracy of products;   
    
*Pure copper winding, uniform winding and stable performance;       

*ABS / PC flame retardant material, high temperature resistance, size stability;
      
*Top cover anti-theft electric design, can be confident to add lead seal, ensure safety.

Order Example

Tamura 200A/5A 0.66kv Low Voltage Toroidal Split Core Current Transformer for Energy Monitoring
Delivery
Tamura 200A/5A 0.66kv Low Voltage Toroidal Split Core Current Transformer for Energy Monitoring
Company information 
Tamura 200A/5A 0.66kv Low Voltage Toroidal Split Core Current Transformer for Energy Monitoring
Ecriree-Tamura is a China-Japan joint venture enterprise specialized in electromagnetic element .
,our enterprise is 50% owned by Japan Tamura Corporation ( ecriee-tamura.en.made-in-china.com ) and 50% by China CETC (Fortune global 500) since 2000.

1.With 800 workers, we specialized in manufacturing electric-magnetic components such as transformer,reactor and inductor for full ranges of Industrial and home appliance application since 2000. 

2.As we are half owned by Japan Tamura group. Our entire quality control management system & technician team are led by our Japanese colleagues.

3.Featured clients:  ABB,  SCHNEIDER, SIEMENZ ,SUNGROW, DIEHL ,, A.O.Smith, MITSUBISH ,FUJI electric. etc.
Tamura 200A/5A 0.66kv Low Voltage Toroidal Split Core Current Transformer for Energy Monitoring
Tamura 200A/5A 0.66kv Low Voltage Toroidal Split Core Current Transformer for Energy Monitoring
Tamura 200A/5A 0.66kv Low Voltage Toroidal Split Core Current Transformer for Energy Monitoring


Tamura 200A/5A 0.66kv Low Voltage Toroidal Split Core Current Transformer for Energy Monitoring
Tamura 200A/5A 0.66kv Low Voltage Toroidal Split Core Current Transformer for Energy Monitoring
FAQ

Q:Are you a Manufacture or Trading company ?
A:We are a Manufacture specialized in making transformer,inductor ,ferrite coil ,common mode choke, etc.
Q:Can I get sample ?
A:Yes. It is our pleasure to provide free samples for you.
Q:How long can I expect to get samples ?
A: Usually it will take about 3-5 working days.
Q:How long can I expect to get products?
A: Depend on item, and normally 3-4 weeks due to we take more procerdures to ensure our quality.
Q: Could I have your catalogue and price list for trial order in MOQ quantity?
A: All of our products are showing on Made-in-China or official website, you are always welcome to ask me to get more information directly
.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
611
Year of Establishment
2000-06-08